QSI 520c Betriebsanweisung Seite 24

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 87
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 23
QSI 500 SERIES USER GUIDE
If a camera has previously been assigned to another role, it
will not appear in the list. For example, if a camera is currently
assigned as the Main camera, it will not appear as an option
in the Guider selection list box.
Ethernet Interface Disabled on QSI 500 Series cameras
Note: If only one camera is connected to the computer, the computer will
always select that camera by default. You do not need to make the selection here.
If two or more cameras are available and they match the serial numbers of the last
camera(s) used for the Main and/or Guider camera, the computer will
automatically reconnect to them in the same roles.
The only time you need to actively make a selection is when you have two or
more cameras available and you want to:
1) Change the camera roles or
2) Select a new camera that has never been connected to this computer before.
Status Indicators
LED Indicator On Uncheck to disable the Status Indicator LED on the back of
the camera. Only normal status indications are disabled.
Visual indication of errors can not be disabled.
Sound On Uncheck to disable the Audible Beeper. Sounds associated
with camera initialization and error notification can not be
disabled.
Fan Mode Can be set to Off, Quiet or Full-Speed. Quiet is the default
setting and is sufficient in most situations.
If Off is selected the fans are disabled unless the camera
temperature begins to exceed a predefined safe level. At that
point the fans are turned on and run at full speed until the
camera temperature is reduced to a safe level. Turning the
fans off is only recommended when there is an alternate
source of cooling such as an external fan or the when
using the Liquid Heat Exchanger.
When in Quiet mode the camera runs the fans at reduced
speed for quieter operation. If more cooling is required to
maintain the setpoint temperature, the fan speed is increased
as needed to maintain the desired temperature.
Full-Speed mode runs the fans at full speed.